Varaoke International Oy

https://varaoke.eu/products/power-plant-energy-supply/power-plant-bfb-boiler-88mw-steam-36kgs-115-bar-525c/

A register description in accordance with Section 10 of the Personal Data Act (523/99)

1. Register holder
Varaoke International Oy
Business ID: 0925191-4
Kullervonkatu 20 B 112
33500 TAMPERE
Tel: +358 10 292 2090

2. Contact person in matters relating to the register
Harri Aikio
Kullervonkatu 20 B 112
33500 TAMPERE

3. Register name
The marketing and analytics register of Varaoke International Oy

4. The purpose of handling personal data
The purpose of the register is to take care of the customer relationship between the register holder and the customer, as well as marketing and communications. The management of the register and the handling of the data can be outsourced to the co-operative partner of the register holder, who has committed to complying with this register description.

5. The data content of the register
The register may contain the following information about the customer:
– Name
– Telephone number
– Address
– E-mail address
– The name and business ID of the organisation
– Contact log

6. Data sources in compliance with the regulations
The register is compiled from the register holder’s customer information system and the visitor tracking tool on the site, publicly available Internet sources and other public sources, both free and payable ones.

7. Passing on of data in compliance with the regulations
The register holder will not pass on the data to outside parties except for the co-operative partner of the register holder mentioned in point 4, unless actions by the Finnish authorities require it to do so.

8. Transferral of data outside the EU or EEA
As a rule, personal data is not transferred outside the European Union or European Economic Area.

9. The principles of the protection of the register
Personal data is kept confidential. The data network and equipment of the register holder and its possible data technology partners, where the register is located, are protected with a firewall and other necessary technical measures.

10. Cookies
Cookies may be used on the pages of the register holder to improve the user experience. A cookie is a text file which is saved on the user’s computer when they visit the web page. It contains information and it is used, amongst other things, to develop marketing and the site. Cookies do not establish the identity of the user. The user can delete cookies from use with the browser settings. The register holder does not guarantee that the site will work correctly after cookies have been deleted.

Sulje [x]

Power Plant (BFB Boiler 88MW, Steam 36kg/s, 115 bar, 525°C)

    Print this page
  • Product ID: VAK10790
  • Name: Power Plant (BFB Boiler 88MW, Steam 36kg/s, 115 bar, 525°C)

Power Plant - Main Equipment


Main Steam Cycle
BFB boiler K7 Fuel Receiving Station and Transportation Gas Boilers K6, K8&K9 Steam Turbines PP BFB-Boiler K7
88 MWth
Foster Wheeler 2001 33,5 kg/s, 90 bar (36 kg/s, 115 bar), 525°C Running time: 88 000 hour Latest revision in 2009 (air preheater) Maintenance revision annually Operation manual in Finnish
Main machinery and key components for K7
Feed water pumps and motors (2 pcs) High-pressure preheater, feed water heater Feed water valves Injection water system Steam drum Combustion chamber Fuel drop funnel (4 pcs) Start-up burners (2 pcs) Load burners (2 pcs) Waste oil burner, waste oil tank Natural gas filters Economiser Air-preheater Super heater Exhaust system Main steam valve Safety valves Dust removing system
Bed material system, bed sand silo
Bed sand preparing Bed lime system, lime silo Furnace ash system
Fly ash system, fly ash silo and screws Primary air blower Secondary air blower Twist grip blower
Bag filter Flue gas blowers (2 pcs) Flue gas scrubbers, lye system, scrubbers sludge system Safety locking system Nitrogen preservation system Chemicals dosage and chemical pumps Sample system Chimney
Solid fuel system for K7

Maintenance revision annually
Raumaster, built in 2001 Operation manual in Finnish
Bar conveyor
Crusher Fuel batching screw, fuel receiving pocket Scraper conveyor to screen hall Screen system Scraper conveyor to silos and scraper conveyor on the silo Peat silo, fuel batching screw Bio fuel silo, fuel batching screw Fuel line from silos Fuel line 1 Fuel line 2 Back-up fuel pocket and fuel batching screw Fuel batching screw at the power plant Robbery fuel batching screw Batching bin 2x50m3 Scraper conveyor at the boiler (2 pcs) Fuel batching pockets and fuel batching screw Fuel feeder (4 pcs) Fuel sample crusher Extinguishing steam system
Sludge system for K7

Built in 2002

Compressor
Sludge pneumatic press Sludge pipe cleaning system Blowpipe to the power plant Cyclone Sludge silo and batching screw Automation and electrical equipment, spare parts for K7

Alcont-control system
Field instruments (as it is on the field) Motors Frequency changers Automatic valves etc. (as it is on the field) Auxiliary devices (as it is on the field) All available existing specific spare parts Radioactive source Excluded!

Steam turbine VP4

Siemens back-pressure turbine
22,5 MW 26 MVA In operation since 2009 Running time: 24 000 h Operation manual in Finnish and English
Turbine
Gearbox Turning gear Generator Generator cooler Oil system Siemens automation system Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts Boiler K6
Built in 1989
100 MWth 36 kg/s, 40 bar, 400° C Operation manual in Finnish Running time: 130 000 h Feed water pumps and motors (2 pcs) Feed water cooler Feed water heater Feed water valves Economiser Steam drum Air preheater Combustion chamber Main steam valv Burners (3 pc), control system Injection water system Exhaust system Combustion air blowers Natural gas system Heavy fuel oil system, dosing tank, pumps Replacement air system Nitrogen preservation system, preservation pump Auxiliary steam system Chimney Safety locking system Safety valves Sample system Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts Boiler K 8
Foster Wheeler 2001
45 MWth 12 bar, 250 C, 1-18kg/s Running time: 17 000 h Operation manual in Finnish
Feed water pumps, common with K9
Feed water valves Economiser Steam drum Combustion chamber Superheater Main steam valve Exhaust system, common with K9 Burners (2 pcs) Combustuin blowers (2 pcs) Replacement air system, common with K9 Light fuel oil system, tank Natural gas system Nitrogen preservation system and preservation pump Safety locking system Safety valves Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts Boiler K9
Foster Wheeler 2001
45 MW MWth 12 bar, sat. 2-19 kg/s Running time: 750 h Operation manual in Finnish
Feed water valves
Economiser Steam drum Combustion chamber Main steam valve Burner Combustion blower Natural gas system Nitrogen preservation system and preservation pump Safety locking system Safety valves Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts Steam turbine VP 2
De Laval back-pressure turbine
10 MWe 16 MVA In operation since 1962 Latest revision in 2008 Running time 2001-2013 50 000 h Operation manual in Finnish
Turbine
Generator Turning gear Lube oil system Cooler system Condensate chamber Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts Water treatment system at the power plant (part of K 7 package, if not othervice needed)
Built in 2006
YIT Raw water purification and desalination Operation manual in Finnish
Raw water purification

Max capacity: 146 m3/h
Capacity: 73m3/h Min capacity: 11 m3/h
Pumps and compressors
Tanks Flock-filtering system (2 pcs) Preheater of raw water Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts
Desalination

Net capacity: 2 x 72 m3/h
Cation exchangers (2 pcs) A1/A2 exchangers (2 pcs) MB exchangers (2 pcs) Tanks Pumps Heat exchanger: dilution water of lye Automation and electrical equipment (as it is on the field) Valves Motors Frequency changers Auxiliary devices (as it is on the field) All available existing specific spare parts Steam, condensate and feed water system (part of K 7 package, if not othervice needed)
Feed water tank
Condensation tank Purification of condensation, precoat-system Condensed steam pumps Steam tanks Steam condenser Reduction valves Steam-pressure accumulator Cooling water system Automation and electrical equipment (as it is on the field) Valves Motors Frequency changers
Compressed air system

Keaser
Air compressor Compressed air dryers Tank
Common electrical equipment
Process central
Distribution transformers 400V 1,25MVA (1 pc)
690V 3,15MVA (2pcs)