Varaoke International Oy

https://varaoke.eu/products/boilers/147mw-steam-turbine-power-plant-60hz1999/

A register description in accordance with Section 10 of the Personal Data Act (523/99)

1. Register holder
Varaoke International Oy
Business ID: 0925191-4
Kullervonkatu 20 B 112
33500 TAMPERE
Tel: +358 10 292 2090

2. Contact person in matters relating to the register
Harri Aikio
Kullervonkatu 20 B 112
33500 TAMPERE

3. Register name
The marketing and analytics register of Varaoke International Oy

4. The purpose of handling personal data
The purpose of the register is to take care of the customer relationship between the register holder and the customer, as well as marketing and communications. The management of the register and the handling of the data can be outsourced to the co-operative partner of the register holder, who has committed to complying with this register description.

5. The data content of the register
The register may contain the following information about the customer:
– Name
– Telephone number
– Address
– E-mail address
– The name and business ID of the organisation
– Contact log

6. Data sources in compliance with the regulations
The register is compiled from the register holder’s customer information system and the visitor tracking tool on the site, publicly available Internet sources and other public sources, both free and payable ones.

7. Passing on of data in compliance with the regulations
The register holder will not pass on the data to outside parties except for the co-operative partner of the register holder mentioned in point 4, unless actions by the Finnish authorities require it to do so.

8. Transferral of data outside the EU or EEA
As a rule, personal data is not transferred outside the European Union or European Economic Area.

9. The principles of the protection of the register
Personal data is kept confidential. The data network and equipment of the register holder and its possible data technology partners, where the register is located, are protected with a firewall and other necessary technical measures.

10. Cookies
Cookies may be used on the pages of the register holder to improve the user experience. A cookie is a text file which is saved on the user’s computer when they visit the web page. It contains information and it is used, amongst other things, to develop marketing and the site. Cookies do not establish the identity of the user. The user can delete cookies from use with the browser settings. The register holder does not guarantee that the site will work correctly after cookies have been deleted.

Sulje [x]

147MW Steam Turbine Power Plant (60Hz,1999)

    Print this page
  • Product ID: VAK11345
  • Name: 147MW Steam Turbine Power Plant (60Hz,1999)

147MW Steam Turbine Power Plant (60Hz,1999)

Manufacturer: Mitsubishi(Japan)

Manufacturing year: 1999

Running hour: 43,970 hours

Output: 147MW (at generator terminal)

Type: exhaust re-heating, re-usable, condensate turbine

Speed: 3600rpm

Fuel: Pulverized Coal

Coal Consumption: 3220kg x 8/h=25.76ton/h

Extraction Stage No.: 7 stages

Main steam pressure: 169kg/cm2G (16.57MPa)

Main steam temperature: 566℃

Reheating steam temperature: 538℃

Reheating steam pressure: 30.4kg/cm2(2.98MPa)

Exhaust room pressure: 722mmHgVac(-0.0959MPa)

-Cooling water: sea water

-condensation of water machine

-Air extractor

-High pressure water supply heater x 3units

-Low pressure water supply heater x 3units

(Generator)

Manufacturer: Mitsubishi(Japan)

Manufacturing year: 1999

Output: 147MW(163,334MVA)

Frequency: 60Hz

Volts: 15,000V

Current: 6287A

Power factor: 0.9

Phase: 3

Pole: 2

Field magnetic current: 1475A

Brushless type

Air cooling

Weight: approx. 180ton

Replace the Stator with a new one: year 2016

Replace the Inner Frame with a new one: year 2018

Replace the Bearing with a new one: year 2019

(Boiler)

Manufacturing year: 1999

Type: Single-body radiation reheating type, natural circulation type

Steam capacity: 460ton/h (100%MCR)

Main steam pressure: 174kg/cm2G (super heater outlet)

Main steam temperature: 569℃ (super heater outlet)

Reheating steam temperature: 541℃9 (re-heater outlet)

Combustion: coal or coal/A-heavy oil

Fuel: Coal (100%MCR), A-heavy oil (35%MCR)

Pulverized coal burners (8 units):  3220 kg/h (per burner)

Coal consumption: 3220kg x 8/h=25.76ton/h

Heavy oil burner (8 units): 1,670 kg/h (per burner)

Heavy oil burner ignition device (8 units):

Electric ignition type gas igniter

Start fuel: A-heavy oil

For ignition: LPG or A-heavy oil

Combustion type: rotation combustion

Main fuel: Pulverized Coal

(Pulverized coal machine)

Supply coal machine: 20ton/h x 3units

Capacity: 18ton /h (270kw) x 3units

Burner (low NOx burner)

(Main equipment list of Boiler)

-Steam drum

-Furnace

-Super heater

-Coal saver

-Renewable air preheater

-Steam-type air preheater

-Ash treatment device

(Main Auxiliary of Power Plant)

-Pulverized coal machine

-Transformer

-Electric type dust collector

-Pure water manufacturing device

-Ammonia supply device

-Air compressor

-Fire extinguishing equipment

-Desulfurization device

De-nitrite device

-Air-ventilation device

-Seawater intake equipment

-Continuous coal unloader (600 tons/h)

-Coal-carrying conveyor

-Coal transport conveyor: 4 units