34MW Gas Turbine Power Plant
-
Print this page
- Product ID: VAK11340
- Name: 34MW Gas Turbine Power Plant
34MW Gas Turbine Power Plant
(1) Commercial Operation Starts: August, 2021
(2) Operating hours: 13,298 hours (as of 16:00 on May 25, 2023)
Expecting total operation hours to March, 2024 to be around 20,000 hours.
(3) There is a steam generator (boiler) that produces steam using exhaust gas.
(4) Steam product:
31.2ton/h (at 7MPaG)
9ton/h (at 1.6MPaG)
(5) Last Maintenance Time:
9th, March, 2023 ~ 30th, March, 2023
(6) The number of start-up: 66 times
A Little Used 34MW Gas Turbine Power Plant (Co-Generation type, 60Hz)
Manufacturer: Kawasaki (Japan)
Manufacturing year: August, 2020
Type: Co-Generation
<Gas Turbine>
Manufacturer: Kawasaki (Japan)
Manufacturing year: August 2020
Condition: A little used
Model: L30A
Fuel: Gas
Electric Output(kWe): 34MW
Type: Simple open cycle, Two-shaft
Compressor: Axial flow 14-stage
Combustor: 8-can
RPM: 5576
Pressure ratio 24.5
Exhaust gas temperature: 502 °C
Heat rate: 8930(Kj/kW-hr)
Exhaust gas mass flow: 333.3(x 1000kg/h)
LHV of Fuel: 35.9(MJ/Nm3)
Thermal efficiency: 41.2%
Heat recovery efficiency: 46.1%
Total LHV thermal efficiency: 85.5%
Overhaul intervals: six years
Required space for Turbine system +Alternator system:
approx. 11m x 25m x11m(Maximum height of air inlet)
<Eco-friendly low NOx emissions>
NOx reduction method: DLE (Dry Low Emission)
NOx: 15 ppm(15%=O2)
Operating range of DLE (Dry Low Emission): 70~100%
< Alternator >
Manufacturer: Meiden (Japan)
Manufacturing year: 2020
Condition: A little used
Type: Synchronous
Rated power: 37,945kVA
Rated current: 1992A
RPM: 1800
Voltage: 11,000 V
Frequency: 60 Hz
Phase: 3
Poles: 4
Power factor: 0.90
Field Voltage: 128V
Field Current: 598A
Weight: 83 ton
Required cooling water: 160m3/h
Lubricant: 110L/min
Weight: approx.84ton
<Steam Absorption Chiller>
Manufacturer: FCO Kawasaki (Japan)
Manufacturing year: August, 2020
Cooling capacity: 2462kW
Cold water flow rate: 423.4m3/h
Outlet temperature: 7°C
Cooling water flow rate: 700m3/h
Inlet temperature: 32°C
Maximum steam consumption: 2695kg/h
Steam inlet pressure: 0.785MPa (Gauge)
Power: 440V, 60HZ
<Ease of maintenance>
Inspection holes are provided at suitable locations so that all flow path faces can be inspected without disassembly. As in existing Kawasaki models, the high-temperature
section of the gas generator module is structured as a horizontally split casing and a multi-can combustor with the aim of shortening the maintenance time for periodic
replacement. In addition, a modular structure design enables easy and fast replacement work in overhauls.
VIDEO OF TURBINE